2026-11-02
A body control module drives a cooling fan through an Automotive Relay. The relay is rated for 40 amperes and the fan draws 25 amperes. The relay fails after 18 months, and the contacts are found welded together. The fan is a DC motor with a wound field, and the motor winding is an inductor. When the relay opens, the magnetic field in the motor winding collapses and generates a voltage spike that far exceeds the battery voltage. The spike sustains an arc across the opening contacts, and the arc melts the contact surface. The welded contacts are the result of the inductive load, not the continuous current. This guide explains why inductive loads demand special arc suppression and how to select the suppression method.
An inductor stores energy in its magnetic field. The energy is proportional to the inductance and the square of the current. When the Automotive Relay opens, the current path is interrupted, and the magnetic field collapses. The collapsing field induces a voltage across the inductor that opposes the change in current. This voltage is called the back electromotive force, or back EMF. The magnitude of the back EMF depends on the inductance and on how quickly the current is interrupted. For a 24 volt system with a 100 millihenry inductor and a 20 ampere current, the back EMF can reach several hundred volts. The contact gap in the relay is only a fraction of a millimeter, and the dielectric strength of the air gap is far below the back EMF. The gap breaks down, and an arc forms. In our factory, we manufacture Automotive Relay units for inductive loads and we test the contact voltage waveform with an oscilloscope. Ningbo Forward Relay Corp., Ltd. has been manufacturing automotive relays for over 18 years.
The energy in the arc is the energy that was stored in the inductor. If the energy is not dissipated by an external suppression device, it is dissipated in the arc, and the arc erodes the contacts. The erosion is not gradual. A single switching event can transfer enough material to create a crater and a matching spike on the opposite contact.
The arc forms in three stages. The first is the metal bridge stage. As the contacts separate, the contact material melts and stretches into a bridge. The bridge breaks and transfers material from one contact to the other. The second is the pre-breakdown stage. The voltage across the gap ionizes the air, and a glow discharge forms. The third is the arc stage. The glow discharge transitions to an arc, and the arc carries the inductor current until the energy is dissipated. The arc temperature is several thousand degrees Celsius, and it melts and vaporizes the contact material. The table below compares the arc energy and the contact life for different load types.
| Load type | Arc energy per operation | Contact life (operations) | Typical failure mode |
| Resistive (heater) | Low | 100,000 – 200,000 | Even erosion |
| Lamp (inrush) | Moderate | 50,000 – 100,000 | Contact welding at inrush |
| DC motor (inductive) | High | 20,000 – 50,000 | Material transfer, welding |
| Solenoid (inductive) | Very high | 10,000 – 30,000 | Crater and spike, welding |
In our factory, we test the contact life of every relay model with an inductive load bank. The load bank uses a motor and a solenoid that simulate the actual vehicle loads. The test records the contact resistance and the contact voltage waveform every 1,000 operations. The relay is considered failed when the contact resistance exceeds the limit or when the contacts weld. Ningbo Forward Relay Corp., Ltd. provides the test report with the relay specification.
The suppression methods fall into two groups: internal and external. The internal methods are built into the Automotive Relay. They include magnetic blowout, contact material selection, and sealed gas filling. The magnetic blowout uses a permanent magnet to deflect the arc away from the contact surface. The contact material is selected for arc resistance, typically silver tin oxide or silver nickel. The sealed gas filling uses a gas mixture that quenches the arc faster than air. The external methods are added to the circuit by the designer. They include the flyback diode, the RC snubber, the metal oxide varistor, and the transient voltage suppressor. The table below compares the four external methods.
| Suppression method | Clamping voltage | Release time effect | Cost | Best for |
| Flyback diode | 0.7 – 1.0 V above supply | Longest delay | Low | Relays where release time is not critical |
| RC snubber | Depends on R and C | Moderate delay | Low | AC and DC loads, general purpose |
| Metal oxide varistor | 1.5 – 2.0 times supply | Short delay | Moderate | DC loads, high energy |
| Transient voltage suppressor | 1.2 – 1.5 times supply | Shortest delay | Higher | DC loads, fast release required |
Relay design engineer's note: The flyback diode is the most common suppression method, but it has a side effect. The diode provides a low impedance path for the inductor current, and the current decays slowly. The slow decay holds the armature in the closed position for a longer time, which increases the release time of the relay. For a fuel pump or a cooling fan, the release time is not critical. For an ABS valve or a transmission solenoid, the release time is critical, and a TVS or a varistor is preferred. In our factory, we recommend the suppression method based on the load and the system requirement. Ningbo Forward Relay Corp., Ltd. provides the release time data for each relay model with each suppression method.
The release time is the time from the removal of the coil voltage to the opening of the contacts. The release time affects the system safety in two ways. The first is the response of the controlled load. A solenoid that must release quickly, such as a fuel injector or an ABS valve, will respond slowly if the relay release is delayed. The second is the wear of the relay itself. A slow release keeps the arc burning for a longer time, which increases the contact erosion. The table below shows the release time for a typical Automotive Relay with different suppression methods.
| Suppression method | Release time | Contact erosion | System impact |
| No suppression | 5 – 8 ms | Very high | Short relay life |
| Flyback diode | 25 – 40 ms | Low | Slow load release |
| RC snubber | 10 – 15 ms | Moderate | Acceptable for most loads |
| Varistor | 8 – 12 ms | Low | Fast enough for most loads |
| TVS | 6 – 10 ms | Low | Fast release, higher cost |
In our factory, we measure the release time with a high speed camera and a contact voltage sensor. The measurement is performed at the rated coil voltage and at the minimum operating voltage. Ningbo Forward Relay Corp., Ltd. provides the release time curve for each relay model and each suppression method.
The specification should include five items. The first is the load inductance and the operating current. The second is the switching frequency. The third is the suppression method and the clamping voltage. The fourth is the release time requirement. The fifth is the relay contact rating and the contact material. The verification should include three tests. The first is the contact voltage waveform test with an oscilloscope. The second is the contact life test with the actual load or an equivalent load bank. The third is the temperature rise test at the rated switching frequency. In our factory, we perform these tests on a sample basis for each relay model and provide the test report with the shipment. Ningbo Forward Relay Corp., Ltd. also offers a circuit review service where our engineers review the suppression circuit and recommend the optimal method.
We recommend that the designer verify the suppression component rating against the back EMF. A diode or a TVS that is rated for the supply voltage but not for the back EMF will fail short, and the relay will not open. The suppression component must be rated for the peak voltage and the peak current of the inductive kick.
Inductive loads demand special arc suppression in Automotive Relay units because the inductor stores energy that must be dissipated when the contacts open. Without suppression, the energy forms an arc that erodes the contacts and can weld them together. The suppression can be internal, through magnetic blowout and contact material, or external, through a flyback diode, RC snubber, varistor, or TVS. The choice depends on the load, the release time requirement, and the cost. The specification should include the load inductance, the current, the switching frequency, the suppression method, and the release time requirement. The verification should include the contact voltage waveform, the contact life test, and the temperature rise test. Ningbo Forward Relay Corp., Ltd. has been manufacturing automotive relays for over 18 years and provides full suppression selection and verification support for our customers.