An ECU design engineer is revising a body control module that has run out of board area. The module has gained four new load outputs in the latest vehicle program, but the housing envelope is fixed by the vehicle package. The engineer reviews the board layout and finds that the plug-in Automotive Relays and their sockets occupy more than 20 percent of the board area. The sockets also add height, and the harness connectors add cost. The engineer proposes replacing the plug-in relays with PCB-mount relays that are soldered directly to the board. The change removes the sockets, removes the harness, and frees board area for the new outputs. This guide explains how PCB-mount relays save space and what to verify before the change.
The ECU enclosure is constrained by the vehicle package. The space under the dashboard, behind the trim panel, or in the engine bay is fixed, and the ECU must fit in that space. At the same time, the number of functions controlled by the ECU increases with every model year. The result is a pressure to fit more function into the same volume. The plug-in Automotive Relays and their sockets are a significant part of the volume. A standard plug-in relay with its socket occupies about 30 by 30 millimeters of board area and 40 millimeters of height. A PCB-mount relay occupies about 20 by 20 millimeters of board area and 25 millimeters of height. The difference is 55 percent of board area and 37 percent of height. In our factory, we produce both plug-in and PCB-mount relays. Ningbo Huaguan Electronics Co., Ltd. has been manufacturing automotive relays for over 12 years.
The board area is not the only issue. The socket adds a second contact interface between the relay and the board. Each interface adds a contact resistance and a potential failure point. The PCB-mount relay removes that interface, which improves the reliability as well as the space.
The plug-in relay is held in a socket, and the socket is soldered to the board. The relay coil and contacts are connected to the socket through the plug-in terminals, and the socket is connected to the board through its own pins. The signal path is board to socket, socket to relay terminal, and relay terminal to the internal contact. The PCB-mount relay is soldered directly to the board. The signal path is board to relay pin, and relay pin to the internal contact. The removal of the socket saves the socket footprint, the socket height, and the socket contact resistance. The removal of the harness connector saves the connector footprint and the harness routing space. The table below compares the two mounting methods.
| Parameter | Plug-in relay with socket | PCB-mount relay |
| Board area per relay | 900 – 1,000 mm² | 400 – 500 mm² |
| Height above board | 35 – 45 mm | 20 – 28 mm |
| Connection interfaces | 3 (board to socket, socket to relay, relay to contact) | 1 (board to relay pin) |
| Assembly steps | 3 (solder socket, insert relay, connect harness) | 1 (reflow solder relay) |
| Contact resistance | Higher (socket adds resistance) | Lower (direct solder joint) |
In our factory, we test the contact resistance of the solder joint and of the plug-in interface. The PCB-mount relay has a contact resistance that is 0.5 to 1.0 milliohm lower than the plug-in relay with socket. This reduces the heat generation at the contact and improves the load capacity margin. Ningbo Huaguan Electronics Co., Ltd. provides the contact resistance test report with each production lot.
The PCB-mount relay must withstand the reflow soldering temperature. The reflow profile peaks at 245 to 260 degrees Celsius for 10 to 30 seconds. The relay must be designed with a high-temperature thermoplastic body and a coil that does not deform at that temperature. The sealed relays that we produce for PCB mounting are rated for the J-STD-020 reflow profile. The reflow process removes the manual insertion step and the wave soldering step. It also improves the solder joint consistency because the reflow oven controls the temperature and the time for every joint on the board. The table below compares the two assembly routes.
| Parameter | Plug-in relay with socket | PCB-mount relay |
| Assembly steps | Wave solder socket, manual insert, harness connect | Reflow solder relay |
| Solder joint consistency | Moderate (wave solder varies) | High (reflow controlled) |
| Rework difficulty | Easy (replace relay) | Moderate (desolder relay) |
| Relay thermal limit | Not exposed to reflow | Must withstand 260°C peak |
| Assembly cost per relay | Higher (3 steps) | Lower (1 step) |
ECU design engineer's note: The reflow process is not without risk. The relay must be qualified for the reflow profile, and the board must be designed with a thermal relief that prevents the relay body from overheating during the reflow. We recommend that the designer verify the relay's reflow rating and that the assembly house use the relay manufacturer's recommended profile. In our factory, we provide the reflow profile recommendation with each PCB-mount relay. Ningbo Huaguan Electronics Co., Ltd. also performs a reflow simulation on a sample of each lot before shipment.
The relay height determines the minimum clearance between the board and the housing cover. If the relay is too tall, the cover cannot be closed, or the cover must be redesigned with a bulge. The relay footprint determines the board area that remains for other components. The pin pitch determines the creepage and clearance distance, which is critical for the high-voltage relays that switch 48 volt loads. The pin coplanarity determines whether the relay sits flat on the board during reflow. A pin that is not coplanar can cause an open solder joint. In our factory, we control the pin coplanarity to within 0.10 millimeters and the body height to within 0.30 millimeters. We measure these dimensions on a vision system for every lot. Ningbo Huaguan Electronics Co., Ltd. provides the dimensional report with the shipment.
We also recommend that the designer keep the high-voltage and low-voltage relays in separate zones on the board. The high-voltage relay requires a larger creepage distance, and the low-voltage relay can use a tighter pitch. Mixing the two in the same zone forces the low-voltage relay to use the larger pitch, which wastes board area.
The specification should include six items. The first is the pin layout and the footprint. The second is the body dimensions and the height tolerance. The third is the reflow rating. The fourth is the contact resistance and the contact rating. The fifth is the coil power consumption. The sixth is the operating temperature range. The verification should include four tests. The first is the coplanarity measurement. The second is the reflow thermal test. The third is the vibration and temperature cycling test. The fourth is the contact resistance test after reflow. In our factory, we perform these tests on a sample basis for each production lot and provide the test report with the shipment. Ningbo Huaguan Electronics Co., Ltd. also offers a design review to help the ECU designer select the correct relay for the board layout.
We recommend that the designer verify the relay height against the housing cover with a 3D model before the board is released. A height error discovered after the board is built is expensive to correct. The 3D model should include the relay, the solder joint, and the cover clearance.
PCB-mount Automotive Relays save space in electronic control units by removing the socket, the harness connector, and the associated height. They also reduce the number of connection interfaces and improve the solder joint consistency through reflow soldering. The relay footprint, height profile, pin coplanarity, and reflow rating determine whether the relay fits in the housing and survives the assembly process. The specification should include the pin layout, the body dimensions, the reflow rating, the contact resistance, and the operating temperature range. The verification should include coplanarity, reflow thermal, vibration, and contact resistance tests. Ningbo Huaguan Electronics Co., Ltd. has been manufacturing automotive relays for over 12 years and provides full PCB-mount relay selection and verification support for ECU designers.